{"title":"Starting control","description":"","products":[{"product_id":"startregler-kvl15-lot-034l0049","title":"Starting Regulator KVL15 Solder 034L0049","description":"\u003ch2\u003eStart Regulator Danfoss KVL15 Solder 16 mm 034L0049\u003c\/h2\u003e\n\nThe start regulator is installed in the suction line before the compressor and protects the compressor against overload during startup after long periods of inactivity or after defrosting (high pressure in the evaporator).\n\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConnection: 16mm ODF\u003c\/li\u003e\n\u003cli\u003eNominal capacity: R134a: 5.3kW, R404A\/R507A: 6.3kW, R407C: 6.5kW\u003c\/li\u003e\n\u003cli\u003eKv value: 3.2m3\/h\u003c\/li\u003e\n\u003cli\u003eMax. permissible operating pressure: 18 bar\u003c\/li\u003e\n\u003cli\u003eTemperature range: -60°C to +130°C\u003c\/li\u003e\n\u003cli\u003eRefrigerants: R134a, R404A, R507A, R407C\u003c\/li\u003e\n\u003cli\u003eSuitable for flammable refrigerants (KVL 12 to KVL 22 with solder connections)\u003c\/li\u003e\n\u003cli\u003eControl range: 0.2 - 6.0 bar\u003c\/li\u003e\n\u003cli\u003eFactory setting: 2 bar\u003c\/li\u003e\n\u003cli\u003eMax. P-band: KVL 12-22: 2.0 bar \/ KVL 28-35: 1.5 bar\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":56649164194169,"sku":"0090240","price":178.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/3273\/0233\/files\/0090200-verflssigungsdruckregler-kvr12-danfossjpg-76090.jpg?v=1774288617"},{"product_id":"startregler-kvl35-lot-034l0052","title":"Start Controller KVL35 Solder 034L0052","description":"\u003ch2\u003eDanfoss KVL35 Solder Start Regulator 35 mm 034L0052\u003c\/h2\u003e\n\nThe start regulator is installed in the suction line before the compressor and protects the compressor against overload during startup after a long shutdown period or after defrosting (high pressure in the evaporator).\n\n\u003ch3\u003eTechnical Data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMax. permissible operating pressure: 18 bar\u003c\/li\u003e\n\u003cli\u003eTemperature range: -60°C to +130°C\u003c\/li\u003e\n\u003cli\u003eRefrigerants: R134a \/ R404A \/ R507A \/ R407C\u003c\/li\u003e\n\u003cli\u003eSuitable for flammable refrigerants (KVL 12 to KVL 22 with solder connections)\u003c\/li\u003e\n\u003cli\u003eControl range: 0.2 - 6.0 bar\u003c\/li\u003e\n\u003cli\u003eFactory setting: 2 bar\u003c\/li\u003e\n\u003cli\u003eMax. P-band: KVL 12 - 22: 2.0 bar, KVL 28 - 35: 1.5 bar\u003c\/li\u003e\n\u003cli\u003eConnection: 35 mm ODF\u003c\/li\u003e\n\u003cli\u003eNominal capacity: R134a: 13.2 kW, R404A\/R507A: 15.9 kW, R407C: 16.4 kW\u003c\/li\u003e\n\u003cli\u003ekv-value: 8.0 m3\/h\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":56649167044985,"sku":"0091730","price":329.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/3273\/0233\/files\/0091529-verflssigungsdruckregler-kvr12-danfoss-1jpg-76104.jpg?v=1774288645"},{"product_id":"startregler-kvl22-lot-034l0045","title":"Start Regulator KVL22 Solder 034L0045","description":"\u003ch2\u003eStart Regulator Danfoss KVL22 Solder 22 mm 034L0045\u003c\/h2\u003e\n\nThe start regulator is installed in the suction line before the compressor and protects the compressor against overload when starting up after long periods of inactivity or after defrosting (high pressure in the evaporator).\n\n\u003ch3\u003eTechnical Data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMax. permissible operating pressure: 18 bar\u003c\/li\u003e\n\u003cli\u003eTemperature range: -60°C to +130°C\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R134a \/ R404A \/ R507A \/ R407C\u003c\/li\u003e\n\u003cli\u003eSuitable for flammable refrigerants (KVL 12 to KVL 22 with solder connections)\u003c\/li\u003e\n\u003cli\u003eControl range: 0.2 - 6.0 bar\u003c\/li\u003e\n\u003cli\u003eFactory setting: 2 bar\u003c\/li\u003e\n\u003cli\u003eMax. P-band: KVL 12 - 22: 2.0 bar, KVL 28 - 35: 1.5 bar\u003c\/li\u003e\n\u003cli\u003eConnection: 22 mm ODF\u003c\/li\u003e\n\u003cli\u003eRated capacity: R134a: 5.3 kW, R404A\/R507A: 6.3 kW, R407C: 6.5 kW\u003c\/li\u003e\n\u003cli\u003ekv value: 3.2 m3\/h\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":56649198010745,"sku":"0091710","price":255.55,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/3273\/0233\/files\/0091529-verflssigungsdruckregler-kvr12-danfoss-1jpg-76113.jpg?v=1774288696"},{"product_id":"startregler-kvl28-lot-034l0051","title":"Start Regulator KVL28 Solder 034L0051","description":"\u003ch2\u003eStarting Pressure Regulator Danfoss KVL28 Solder 28 mm 034L0051\u003c\/h2\u003e\n\nThe starting pressure regulator is installed in the suction line before the compressor and protects the compressor against overload when starting after a long standstill or after defrosting (high pressure in the evaporator).\n\n\u003ch3\u003eTechnical Data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emax. permissible operating pressure: 18 bar\u003c\/li\u003e\n\u003cli\u003eTemperature range: -60°C to +130°C\u003c\/li\u003e\n\u003cli\u003eRefrigerants: R134a \/ R404A \/ R507A \/ R407C\u003c\/li\u003e\n\u003cli\u003esuitable for flammable refrigerants (KVL 12 to KVL 22 with solder connections)\u003c\/li\u003e\n\u003cli\u003eControl range: 0.2 - 6.0 bar\u003c\/li\u003e\n\u003cli\u003eFactory setting: 2 bar\u003c\/li\u003e\n\u003cli\u003emax. P-band: KVL 12 - 22: 2.0 bar, KVL 28 - 35: 1.5 bar\u003c\/li\u003e\n\u003cli\u003eConnection: 28 mm ODF\u003c\/li\u003e\n\u003cli\u003eNominal capacity: R134a: 13.2 kW, R404A\/R507A: 15.9 kW, R407C: 16.4 kW\u003c\/li\u003e\n\u003cli\u003ekv value: 8.0 m3\/h\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":56649198043513,"sku":"0091720","price":368.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/3273\/0233\/files\/0091529-verflssigungsdruckregler-kvr12-danfoss-1jpg-76114.jpg?v=1774288696"},{"product_id":"startregler-kvl12-lot-034l0048","title":"Start Regulator KVL12 Solder 034L0048","description":"\u003ch2\u003eStart Regulator KVL12 Solder 12 mm Danfoss 034L0048\u003c\/h2\u003e\n\nThe start regulator is installed in the suction line before the compressor and protects the compressor against overload during start-up after a long shutdown period or after defrosting (high pressure in the evaporator).\n\n\u003ch3\u003eTechnical Data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConnection: 12mm ODF\u003c\/li\u003e\n\u003cli\u003eNominal capacity: R134a: 5.3kW, R404A\/R507A: 6.3kW, R407C: 6.4kW\u003c\/li\u003e\n\u003cli\u003eKv-value: 3.2m3\/h\u003c\/li\u003e\n\u003cli\u003eMax. permissible operating pressure: 18bar\u003c\/li\u003e\n\u003cli\u003eTemperature range: -60°C to +130°C\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R134a, R404A, R507A, R407C\u003c\/li\u003e\n\u003cli\u003eSuitable for flammable refrigerants (KVL 12 to KVL 22 with solder connections)\u003c\/li\u003e\n\u003cli\u003eControl range: 0.2 - 6.0 bar\u003c\/li\u003e\n\u003cli\u003eFactory setting: 2 bar\u003c\/li\u003e\n\u003cli\u003eMax. P-band: KVL 12 - 22; 2.0 bar \/ KVL 28-35: 1.5 bar\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":56649560129913,"sku":"0090200","price":180.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/3273\/0233\/files\/0090200-verflssigungsdruckregler-kvr12-danfossjpg-76775.jpg?v=1774289636"},{"product_id":"startregler-kvl12-bordel-034l0041","title":"Start Control KVL12 Flare 034L0041","description":"\u003ch2\u003eDanfoss KVL12 Start Regulator Flare 12 mm 034L0041\u003c\/h2\u003e\n\nA starting regulator is installed in the suction line before the compressor to protect it from overload when starting up after a long standstill or after defrosting (high pressure in the evaporator).\n\n\u003ch3\u003eTechnical Data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConnection: 3\/4\"-16 UNF, 1\/2\" SAE\u003c\/li\u003e\n\u003cli\u003eNominal capacity: R134a: 5.3kW, R404A\/R507A: 6.3kW, R407C: 6.4kW\u003c\/li\u003e\n\u003cli\u003ekv-value: 3.2m3\/h\u003c\/li\u003e\n\u003cli\u003emax. permissible operating pressure: 18bar\u003c\/li\u003e\n\u003cli\u003eTemperature range: -60°C to +130°C\u003c\/li\u003e\n\u003cli\u003eRefrigerants: R134a, R404A, R507A, R407C\u003c\/li\u003e\n\u003cli\u003esuitable for flammable refrigerants (KVL 12 to KVL 22 with solder connections)\u003c\/li\u003e\n\u003cli\u003eControl range: 0.2 - 6.0 bar\u003c\/li\u003e\n\u003cli\u003eFactory setting: 2 bar\u003c\/li\u003e\n\u003cli\u003emax. P-band: KVL 12 - 22; 2.0 bar \/ KVL 28-35: 1.5 bar\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":56649585688953,"sku":"0090201","price":178.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/3273\/0233\/files\/0090201-startregler-kvl12-brdel-034l0041jpg-76948.jpg?v=1774289886"},{"product_id":"startregler-kvl15-bordel-034l0042","title":"Starting Regulator KVL15 Flare 034L0042","description":"\u003ch2\u003eDanfoss KVL15 Flare 16 mm 034L0042 Start Regulators\u003c\/h2\u003e\n\nThe starting regulator is installed in the suction line before the compressor and protects the compressor against overload when starting after a long standstill or after defrosting (high pressure in the evaporator).\n\n\u003ch3\u003eTechnical Data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConnection: 7\/8\" - 14 UNF, 5\/8\" SAE\u003c\/li\u003e\n\u003cli\u003eNominal capacity: R134a: 5.3kW, R404A\/R507A: 6.3kW, R407C: 6.4kW\u003c\/li\u003e\n\u003cli\u003eKv value: 3.2m³\/h\u003c\/li\u003e\n\u003cli\u003eMax. permissible operating pressure: 18 bar\u003c\/li\u003e\n\u003cli\u003eTemperature range: -60°C to +130°C\u003c\/li\u003e\n\u003cli\u003eRefrigerants: R134a, R404A, R507A, R407C\u003c\/li\u003e\n\u003cli\u003eSuitable for flammable refrigerants (KVL 12 to KVL 22 with solder connections)\u003c\/li\u003e\n\u003cli\u003eControl range: 0.2 - 6.0 bar\u003c\/li\u003e\n\u003cli\u003eFactory setting: 2 bar\u003c\/li\u003e\n\u003cli\u003eMax. P-band: KVL 12-22: 2.0 bar \/ KVL 28-35: 1.5 bar\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":56649585721721,"sku":"0090241","price":178.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/3273\/0233\/files\/0090201-startregler-kvl12-brdel-034l0041jpg-76949.jpg?v=1774289887"},{"product_id":"startregler-prc-11b-lot-800385","title":"Starter Regulator PRC-11B Solder 800385","description":"\u003ch2\u003eCrankcase Pressure Regulators Alco PRC-11B Solder 22 mm 7\/8\" | 800385\u003c\/h2\u003e\n\nThe crankcase pressure regulator is installed in the suction line before the compressor and protects the compressor against overload when starting up after a long standstill or after defrosting (high pressure in the evaporator).\n\n\u003ch3\u003eTechnical Data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConnection: 22mm, 7\/8\" ODF\u003c\/li\u003e\n\u003cli\u003eNominal capacity: R134a: 3.0kW, R404A\/R507A: 4.5kW, R407C: 4.5kW\u003c\/li\u003e\n\u003cli\u003eMax. permissible operating pressure: 25 bar\u003c\/li\u003e\n\u003cli\u003eMedium temperature range: -30°C to +80°C\u003c\/li\u003e\n\u003cli\u003eRefrigerants: HFC, HCFC\u003c\/li\u003e\n\u003cli\u003eControl range: 0.5 - 6.9 bar\u003c\/li\u003e\n\u003cli\u003eFactory setting: 2 bar\u003c\/li\u003e\n\u003cli\u003ePressure change per turn: Valve size 1 (PRC-11x): 0.6 bar, Valve size 2 (PRC-21x): 0.4 bar\u003c\/li\u003e\n\u003cli\u003ewith pressure port: 7\/16-20 UNF \/ 1\/4\" SAE\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Alco","offers":[{"title":"Default Title","offer_id":56649585852793,"sku":"0090202","price":164.7,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/3273\/0233\/files\/0090202-startregler-prc-11b-lt-800385jpg-76950.jpg?v=1774289889"},{"product_id":"startregler-prc-21e-lot-800388","title":"Starter Regulator PRC-21E Solder 800388","description":"\u003ch2\u003eStart Regulator Alco PRC-21E Solder 35 mm \/ 1 3\/8\" | 800388\u003c\/h2\u003e\n\nThe start regulator is installed in the suction line before the compressor and protects the compressor against overload when starting after a long standstill or after defrosting (high pressure in the evaporator).\n\n\u003ch3\u003eTechnical Data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConnection: 35mm, 1 3\/8\" inch ODF\u003c\/li\u003e\n\u003cli\u003eNominal Capacity: R134a: 7.4kW, R404A\/R507A: 11.1kW, R407C: 11.1kW\u003c\/li\u003e\n\u003cli\u003eMax. permissible operating pressure: 25 bar\u003c\/li\u003e\n\u003cli\u003eMedium temperature range: -30°C to +80°C\u003c\/li\u003e\n\u003cli\u003eRefrigerant: HFC, HCFC\u003c\/li\u003e\n\u003cli\u003eControl range: 0.5 - 6.9 bar\u003c\/li\u003e\n\u003cli\u003eFactory setting: 2 bar\u003c\/li\u003e\n\u003cli\u003ePressure change per revolution: Valve size 1 (PRC-11x): 0.6 bar, Valve size 2 (PRC-21x): 0.4 bar\u003c\/li\u003e\n\u003cli\u003ewith pressure port: 7\/16-20 UNF \/ 1\/4\" SAE\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Alco","offers":[{"title":"Default Title","offer_id":56649585983865,"sku":"0090203","price":276.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/3273\/0233\/files\/0090202-startregler-prc-11b-lt-800385jpg-76951.jpg?v=1774289890"},{"product_id":"leistungsregler-kvc15-lot-034l0147","title":"Power Regulator KVC15 Solder 034L0147","description":"\u003ch2\u003eCapacity Regulator KVC15 Solder 16 mm Danfoss 034L0147\u003c\/h2\u003e\n\nThe KVC is a capacity regulator for adapting the compressor capacity to the actual evaporator load. When installed in a bypass between the high and low pressure sides in refrigeration systems, the KVC sets a lower limit for the compressor's suction pressure by allowing hot gas\/cold gas to flow from the high-pressure side to the low-pressure side as substitute capacity.\n\n\u003ch3\u003eTechnical Data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMax. permissible operating pressure: 28 bar\u003c\/li\u003e\n\u003cli\u003eTemperature range: -45°C to +130°C\u003c\/li\u003e\n\u003cli\u003eRefrigerants: R134a \/ R404A \/ R507A \/ R407C\u003c\/li\u003e\n\u003cli\u003eSuitable for flammable refrigerants (KVC 12 to KVC 22 with solder connections)\u003c\/li\u003e\n\u003cli\u003eControl range: 0.2 - 6.0 bar\u003c\/li\u003e\n\u003cli\u003eFactory setting: 2 bar\u003c\/li\u003e\n\u003cli p-band: bar\u003e\n\u003c\/li\u003e\n\u003cli\u003eConnection: 16mm ODF\u003c\/li\u003e\n\u003cli\u003eNominal capacity: R134a: 9.4 kW, R 404A\/R507A: 13.6 kW, R407C: 16.4 kW\u003c\/li\u003e\n\u003cli\u003ekv-value: 1.25 m3\/h\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":56649779085689,"sku":"0091731","price":167.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/3273\/0233\/files\/0091731-leistungsregler-kvc15-lt-034l0147jpg-74888.jpg?v=1774290737"},{"product_id":"leistungsregler-kvc12-bordel-034l0141","title":"Capacity regulator KVC12 Flare 034L0141","description":"\u003ch2\u003eCapacity Regulator KVC12 Flare 12 mm Danfoss 034L0141\u003c\/h2\u003e\n\nThe KVC is a capacity regulator used to adapt compressor capacity to the actual evaporator load. When installed in a bypass between the high and low-pressure sides in refrigeration systems, the KVC sets a lower limit for the compressor's suction pressure by allowing hot gas\/cold gas to bypass from the high-pressure side to the low-pressure side as replacement capacity.\n\n\u003ch3\u003eTechnical Data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMax. permissible operating pressure: 28 bar\u003c\/li\u003e\n\u003cli\u003eTemperature range: -45°C to +130°C\u003c\/li\u003e\n\u003cli\u003eRefrigerants: R134a \/ R404A \/ R507A \/ R407C\u003c\/li\u003e\n\u003cli\u003eSuitable for flammable refrigerants (KVC 12 to KVC 22 with solder connections)\u003c\/li\u003e\n\u003cli\u003eControl range: 0.2 - 6.0 bar\u003c\/li\u003e\n\u003cli\u003eFactory setting: 2 bar\u003c\/li\u003e\n\u003cli p-band: bar\u003e\n\u003c\/li\u003e\n\u003cli\u003eConnection: 3\/4\"-16 UNF, 1\/2\" SAE\u003c\/li\u003e\n\u003cli\u003eNominal capacity: R134a: 4.8 kW, R 404A\/R507A: 6.9 kW, R407C: 8.4 kW\u003c\/li\u003e\n\u003cli\u003ekv-value: 0.68 m3\/h\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":56649779118457,"sku":"0091732","price":167.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/3273\/0233\/files\/0091732-leistungsregler-kvc12-brdel-034l0141jpg-74889.jpg?v=1774290737"},{"product_id":"leistungsregler-kvc15-bordel-034l0142","title":"Power Regulator KVC15 Flare 034L0142","description":"\u003ch2\u003eCapacity Regulator KVC15 Brödel 16 mm Danfoss 034L0142\u003c\/h2\u003e\n\nThe KVC is a capacity regulator used to adapt compressor capacity to the actual evaporator load. When installed in a bypass between the high and low-pressure sides in refrigeration systems, the KVC sets a lower limit for the compressor's suction pressure by allowing hot gas\/cold gas to flow from the high-pressure side to the low-pressure side as replacement capacity.\n\n\u003ch3\u003eTechnical Data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMax. permissible operating pressure: 28 bar\u003c\/li\u003e\n\u003cli\u003eTemperature range: -45°C to +130°C\u003c\/li\u003e\n\u003cli\u003eRefrigerants: R134a \/ R404A \/ R507A \/ R407C\u003c\/li\u003e\n\u003cli\u003eSuitable for flammable refrigerants (KVC 12 to KVC 22 with solder connections)\u003c\/li\u003e\n\u003cli\u003eControl range: 0.2 - 6.0 bar\u003c\/li\u003e\n\u003cli\u003eFactory setting: 2 bar\u003c\/li\u003e\n\u003cli p-band: bar\u003e\n\u003c\/li\u003e\n\u003cli\u003eConnection: 7(7\"-14 UNF, 5\/8\" SAE\u003c\/li\u003e\n\u003cli\u003eNominal capacity: R134a: 9.4 kW, R 404A\/R507A: 13.6 kW, R407C: 16.4 kW\u003c\/li\u003e\n\u003cli\u003ekv-value: 1.25 m3\/h\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":56649779183993,"sku":"0091733","price":167.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/3273\/0233\/files\/0091732-leistungsregler-kvc12-brdel-034l0141jpg-74890.jpg?v=1774290738"},{"product_id":"leistungsregler-kvc12-lot-034l0146","title":"Capacity Regulator KVC12 Solder 034L0146","description":"\u003ch2\u003eCapacity Regulator KVC12 Solder 12 mm Danfoss 034L0146\u003c\/h2\u003e\n\nThe KVC is a capacity regulator used to adapt compressor capacity to the actual evaporator load. When installed in a bypass between the high and low-pressure sides in refrigeration systems, the KVC sets a lower limit for the compressor's suction pressure by allowing hot gas\/cold gas to flow from the high-pressure side to the low-pressure side as replacement capacity.\n\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMax. permissible operating pressure: 28 bar\u003c\/li\u003e\n\u003cli\u003eTemperature range: -45°C to +130°C\u003c\/li\u003e\n\u003cli\u003eRefrigerants: R134a \/ R404A \/ R507A \/ R407C\u003c\/li\u003e\n\u003cli\u003eSuitable for flammable refrigerants (KVC 12 to KVC 22 with solder connections)\u003c\/li\u003e\n\u003cli\u003eControl range: 0.2 - 6.0 bar\u003c\/li\u003e\n\u003cli\u003eFactory setting: 2 bar\u003c\/li\u003e\n\u003cli p-band: bar\u003e\n\u003c\/li\u003e\n\u003cli\u003eConnection: 12mm ODF\u003c\/li\u003e\n\u003cli\u003eRated capacity: R134a: 4.8 kW, R 404A\/R507A: 6.9 kW, R407C: 8.4 kW\u003c\/li\u003e\n\u003cli\u003ekv value: 0.68 m3\/h\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":56649779347833,"sku":"0091734","price":178.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/3273\/0233\/files\/0091731-leistungsregler-kvc15-lt-034l0147jpg-74891.jpg?v=1774290739"},{"product_id":"leistungsregler-kvc22-lot-034l0144","title":"Capacity regulator KVC22 Solder 034L0144","description":"\u003ch2\u003eCapacity Regulator KVC22 Solder 22 mm Danfoss 034L0144\u003c\/h2\u003e\n\nThe KVC is a capacity regulator used to adapt compressor capacity to the actual evaporator load. When installed as a bypass between the high and low-pressure sides in refrigeration systems, the KVC sets a lower limit for the compressor's suction pressure by allowing hot gas\/cold gas to flow from the high-pressure side to the low-pressure side as replacement capacity.\n\n\u003ch3\u003eTechnical Data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMax. permissible operating pressure: 28 bar\u003c\/li\u003e\n\u003cli\u003eTemperature range: -45°C to +130°C\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R134a \/ R404A \/ R507A \/ R407C\u003c\/li\u003e\n\u003cli\u003eSuitable for flammable refrigerants (KVC 12 to KVC 22 with solder connections)\u003c\/li\u003e\n\u003cli\u003eControl range: 0.2 - 6.0 bar\u003c\/li\u003e\n\u003cli\u003eFactory setting: 2 bar\u003c\/li\u003e\n\u003cli p-band: bar\u003e\n\u003c\/li\u003e\n\u003cli\u003eConnection: 22mm ODF\u003c\/li\u003e\n\u003cli\u003eNominal capacity: R134a: 12.0 kW, R 404A\/R507A: 17.4 kW, R407C: 21.0 kW\u003c\/li\u003e\n\u003cli\u003eKv value: 1.85 m3\/h\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":56649779413369,"sku":"0091735","price":247.7,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/3273\/0233\/files\/0091731-leistungsregler-kvc15-lt-034l0147jpg-74892.jpg?v=1774290739"},{"product_id":"leistungsregler-cpce-12-bordel-034n0081","title":"Capacity Regulator CPCE 12 Flare 034N0081","description":"\u003ch2\u003eCapacity Regulator CPCE 12 Flare 12 mm Danfoss 034N0081\u003c\/h2\u003e\n\nCPCE capacity regulators adjust the compressor capacity to the actual evaporator load. They are designed for installation in a bypass line between the high and low-pressure sides of the refrigeration system for hot gas injection between the evaporator and the thermostatic expansion valve. The injection should be performed by an LG hot gas mixer.\n\n\u003ch3\u003eTechnical Data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emax. permissible operating pressure: 28 bar\u003c\/li\u003e\n\u003cli\u003eTemperature range: -50°C to +140°C\u003c\/li\u003e\n\u003cli\u003eRefrigerants: R134a \/ R404A \/ R507A \/ R407C\u003c\/li\u003e\n\u003cli\u003esuitable for flammable refrigerants (CPCE 12 to CPCE 22 with solder connections and LG 12 - 16 to LG 12 - 22)\u003c\/li\u003e\n\u003cli\u003eControl range: 0 to 6 bar\u003c\/li\u003e\n\u003cli\u003eFactory setting: 0.4 bar\u003c\/li\u003e\n\u003cli\u003emax. differential pressure: 18 bar\u003c\/li\u003e\n\u003cli\u003ewith control pressure connection 1\/4\" SAE \/ 7\/16\"-20 UNF for the control line\u003c\/li\u003e\n\u003cli\u003eConnection: 3\/4\"-16 UNF, 1\/2\" SAE\u003c\/li\u003e\n\u003cli\u003eRated capacity: R134a: 7.9 kW, R404A\/R507A: 16.4 KW, R407C: 19.0 kW\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":56649779446137,"sku":"0091736","price":350.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/3273\/0233\/files\/0091732-leistungsregler-kvc12-brdel-034l0141jpg-74893.jpg?v=1774290740"},{"product_id":"leistungsregler-cpce-12-lot-034n0082","title":"Capacity regulator CPCE 12 Solder 034N0082","description":"\u003ch2\u003eCapacity regulator CPCE 12 Solder 12 mm Danfoss 034N0082\u003c\/h2\u003e\n\nCPCE capacity regulators adapt the compressor capacity to the actual evaporator load. They are designed for installation in a bypass line between the high and low pressure sides of the refrigeration system for hot gas injection between the evaporator and the thermostatic expansion valve. The injection should be done by an LG hot gas mixer.\n\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emax. permissible operating pressure: 28 bar\u003c\/li\u003e\n\u003cli\u003eTemperature range: -50°C to +140°C\u003c\/li\u003e\n\u003cli\u003eRefrigerants: R134a \/ R404A \/ R507A \/ R407C\u003c\/li\u003e\n\u003cli\u003eSuitable for flammable refrigerants (CPCE 12 to CPCE 22 with solder connections and LG 12 - 16 to LG 12 - 22)\u003c\/li\u003e\n\u003cli\u003eControl range: 0 to 6 bar\u003c\/li\u003e\n\u003cli\u003eFactory setting: 0.4 bar\u003c\/li\u003e\n\u003cli\u003emax. differential pressure: 18 bar\u003c\/li\u003e\n\u003cli\u003ewith control pressure connection 1\/4\" SAE \/ 7\/16\"-20UNF for the control line\u003c\/li\u003e\n\u003cli\u003eConnection: 12.70mm ODF\u003c\/li\u003e\n\u003cli\u003eNominal capacity: R134a: 7.9kW, R404A\/R507A: 16.4 kW, R407C: 19.0 kW\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":56649779609977,"sku":"0091737","price":350.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/3273\/0233\/files\/0091732-leistungsregler-kvc12-brdel-034l0141jpg-74894.jpg?v=1774290741"},{"product_id":"leistungsregler-cpce-15-lot-034n0083","title":"Pressure Regulator CPCE 15 Solder 034N0083","description":"\u003ch2\u003eCPCE 15 Capacity Regulator Solder 16 mm Danfoss 034N0083\u003c\/h2\u003e\n\nCPCE capacity regulators adapt compressor capacity to the actual evaporator load. They are designed for installation in a bypass line between the high and low-pressure sides of the refrigeration system for hot gas injection between the evaporator and the thermostatic expansion valve. Injection should be carried out using an LG hot gas mixer.\n\n\u003ch3\u003eTechnical Data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMax. permissible operating pressure: 28 bar\u003c\/li\u003e\n\u003cli\u003eTemperature range: -50°C to +140°C\u003c\/li\u003e\n\u003cli\u003eRefrigerants: R134a \/ R407A \/ R507A \/ R407C\u003c\/li\u003e\n\u003cli\u003eSuitable for flammable refrigerants (CPCE 12 to CPCE 22 with solder connections and LG 12 - 16 to LG 12 - 22)\u003c\/li\u003e\n\u003cli\u003eControl range: 0 to 6 bar\u003c\/li\u003e\n\u003cli\u003eFactory setting: 0.4 bar\u003c\/li\u003e\n\u003cli\u003eMax. differential pressure: 18 bar\u003c\/li\u003e\n\u003cli\u003eWith pilot pressure port 1\/4\"SAE \/ 7\/16\"UNF for the pilot line\u003c\/li\u003e\n\u003cli\u003eConnection: 15.88 mm ODF\u003c\/li\u003e\n\u003cli\u003eNominal capacity: R134a: 11.6 kW, R404A\/R507A: 24.2 kW, R407C: 27.9 kW\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":56649779675513,"sku":"0091738","price":397.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/3273\/0233\/files\/0091732-leistungsregler-kvc12-brdel-034l0141jpg-74895.jpg?v=1774290742"},{"product_id":"leistungsregler-cpce-22-lot-034n0084","title":"CPCE 22 Löt 034N0084 Power Controller","description":"\u003ch2\u003eCapacity Regulator CPCE 22 Solder 22 mm Danfoss 034N0084\u003c\/h2\u003e\n\nCPCE capacity regulators adapt compressor capacity to the actual evaporator load. They are designed for installation in a bypass line between the high- and low-pressure sides of the refrigeration system for hot gas injection between the evaporator and the thermostatic expansion valve. Injection should be carried out using an LG hot gas mixer.\n\n\u003ch3\u003eTechnical Data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emax. permissible operating pressure: 28 bar\u003c\/li\u003e\n\u003cli\u003eTemperature range: -50°C to +140°C\u003c\/li\u003e\n\u003cli\u003eRefrigerants: R134a \/ R407A \/ R507A \/ R407C\u003c\/li\u003e\n\u003cli\u003eSuitable for flammable refrigerants (CPCE 12 to CPCE 22 with solder connections and LG 12 - 16 to LG 12 - 22)\u003c\/li\u003e\n\u003cli\u003eControl range: 0 to 6 bar\u003c\/li\u003e\n\u003cli\u003eFactory setting: 0.4 bar\u003c\/li\u003e\n\u003cli\u003emax. differential pressure: 18 bar\u003c\/li\u003e\n\u003cli\u003ewith pilot pressure port 1\/4\"SAE \/ 7\/16\"UNF for the pilot line\u003c\/li\u003e\n\u003cli\u003eConnection: 22.23mm ODF\u003c\/li\u003e\n\u003cli\u003eNominal capacity: R134a: 15.2 kW, R 404A\/R507A: 32.0 kW, R407C: 37.1 kW\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":56649779708281,"sku":"0091739","price":469.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/3273\/0233\/files\/0091732-leistungsregler-kvc12-brdel-034l0141jpg-74896.jpg?v=1774290743"}],"url":"https:\/\/kaelte4you.de\/en\/collections\/startregler.oembed","provider":"Kälte4You","version":"1.0","type":"link"}